Product Identification
Product ID:140-9077 SAFETY GREEN
MSDS Date:12/01/1992
FSC:8010
NIIN:00F017751
MSDS Number: BYHVC
Responsible Party
CLEVELAND, OH 44115-1042
US
Emergency Phone: 216-566-2917/216-566-2902
Info Phone: 216-566-2902/216-566-2917
Cage: 54636
Contractor
Telephone: 800-251-2486/216-566-2242
Cage: 54636
Ingredients
TOLUENE (IARC CARC- GROUP 3) *95-3*
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 11%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
PROPANE (DIMETHYLMETHANE) *95-3*
CAS: 74-98-6
RTECS: TX2275000
Fraction By Weight: 8%
OSHA PEL 1000 PPM
ACGIH TLV: SIMPLE ASPHYXIANT
ISOBUTANE, 2-METHYLPROPANE
CAS: 75-28-5
RTECS: TZ4300000
Fraction By Weight: 8%
OSHA PEL 1800 MG/CUM
ACGIH TLV: 1000 PPM
KEROSENE (PETROLEUM), HYDROTREATED (C10-C15 SATURATED
CAS: 64742-47-8
RTECS: OA5504000
Fraction By Weight: 22%
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY CAUSE IRRITATION OF EYES, SKIN &
RESPIRATORY SYSTEM, NERVOUS SYSTEM DEPRESSION. OVEREXPOSURE MAY
RESULT IN DEATH. PROLONGED OVEREXPOSURE TO SOLVENTS MAY CAUSE
ADVERSE EFFECTS TO THE LIVER, URINARY , BLOOD FORMING &
CARDIOVASCULAR SYSTEMS. OVEREXPOSURE TO SOLVENTS MAY CAUSE
PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, UNCONSCIOUSNESS, HEADACHE,
DIZZINESS, NAUSEA, LOSS OF COORDINATION, REDNESS, ITCHING, BURNING
SENSATION
Medical Cond Aggravated by Exposure:NONE
First Aid
First Aid:INHALATION: REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP
WARM & QUIET. SKIN: WASH THOROUGHLY W/SOAP & WATER. EYES: FLUSH
W/LARGE AMOUNTS OF WATER FOR 15 MINS. INGESTION: NEVER GIVE
ANYTHING BY MOUTH IF UNCONSCIOUS. DON'T INDUCE VOMITING. GIVE
SEVERAL GLASSES OF WATER. OBTAIN MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Flash Point:<0F
Lower Limits:1
Upper Limits:7
Extinguishing Media:CO2, DRY CHEMICAL, ALCOHOL FOAM
Fire Fighting Procedures:WEAR FULL PROTECTIVE EQUIPMENT & SCBA. WATER
SPRAY MAY BE INEFFECTIVE. IF WATER IS USED, FOG NOZZLES ARE
PREFERABLE. WATER MAY BE USED TO COOL CLOSED CONTAINERS
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. VAPORS WILL ACCUMULATE READILY & MAY
IGNITE EXPLOSIVELY.
Accidental Release
Spill Release Procedures:REMOVE ALL IGNITION SOURCES. VENTILATE &
REMOVE W/INERT ABSORBENT.
Handling
Handling and Storage Precautions:KEEP FROM IGNITION SOURCES. DURING USE
& UNTIL ALL VAPORS ARE GONE: KEEP AREA VENTILATED & EXTINGUISH ALL
IGNITION SOURCES. KEEP OUT CHILDRENS' REACH.
Other Precautions:CONSULT NFPA CODE, USE APPROVED BONDING & GROUNDING
PROCEDURES. DON'T PUNCTURE/INCINERATE/EXPOSE TO TEMP >120F. AVOID
CONTACT W/SKIN/EYES & BREATHING OF VAPORS. HEAT, SUNLIGHT,
RADIATORS, STOVES, HOT WATER COULD CAUSE CONTAINER TO BURST.
Exposure Controls
Respiratory Protection:IF EXPOSURE CANNOT BE CONTROLLED
VAPOR/PARTICULATE RESPIRATOR APPROVED BY NIOSH/MSHA. WHEN
SANDING/ABRADING THE DRIED FILM, WEAR A DUS T/MIST RESPIRATOR
APPROVED BY NIOSH/MSHA
Ventilation:LOCAL EXHAUST PREFERABLE. GENERAL EXHAUST ACCEPTABLE IF
EXPOSURE IS MAINTAINED
Eye Protection:REQUIRED
Other Protective Equipment:SAFETY SPECTACLES W/UNPERFORATED SIDESHIELDS
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE. WASH HANDS AFTER USING.
Supplemental Safety and Health
INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING/INHALING THE CONTENTS
CAN BE HARMFUL/FATAL. DON'T TAKE INTERNALLY.
Chemical Properties
Boiling Pt:B.P. Text:<0-412F
Vapor Density:>1
Evaporation Rate & Reference:FASTER THAN ETHER
Percent Volatiles by Volume:>75
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAME, HOT SURFACES,
SUNLIGHT, TEMPERATURES >120F & OTHER IGNITION SOURCES
Hazardous Decomposition Products:BY FIRE: CO2, CO
Disposal
Waste Disposal Methods:WASTE MUST BE TESTED FOR IGNITABILITY TO
DETERMINE THE APPLICABLE EPA HAZARDOUS WASTE NUMBER. INCINERATE IN
APPROVED FACILITY. DON'T INCINERATE CLOSED CONTAINERS. DISPOSE OF
IAW/LOCAL, STATE & FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.